The TX series of Signal Isolators and Transducers comprise a wide range of DC and AC Analog signal converters to optically isolated signals with excellent linearity and load driving capability. The Transducers are available in standard DIN-Rail mount execution. Options include Digital Indication, Control Relay outputs, higher load driving capability, Multiple analog outputs, weather-proof/flame-proof/panel mount options, etc. All ASHE instruments carry a lifetime warranty against defects in components and workmanship.
Product Details:
| Application | Tap Position Transmitter |
| Brand | ASHE |
| Country of Origin | Made in India |
| Dimensions | 100 x 22 x 110 mm [H x W x D] |
| Input Signal | OLTC On load Tap Changer input or Variable Resistance in Ohms |
| Isolation Level | 1.5 kV rms for one minute |
| Isolation Type | Optical and Galvanic |
| Linearity | 0.1% |
| Model Number | TX-242 |
| Output Signal | Two isolated outputs of 4 to 20 mA DC (or as required) |
|
RESISTANCE ISOLATING REPEATER |
||
|
|
||
|
Model |
: |
ASHE TX-242. |
|
Type |
: |
Resistance signal multiplication with isolation, buffering and amplification. |
|
Application |
: |
Transformer Tap Position Transmission. |
|
Input signal |
: |
0 to 1 K-Ohm variable resistance (3-wire), or as required. |
|
Output |
: |
Two nos. isolated linear analog signals. |
|
Output signal 1 |
: |
4 to 20 mA DC. |
|
Output signal 2 |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms for each output. |
|
Accuracy class |
: |
±0.5%. |
|
Isolation |
: |
Between Input // Outputs // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external – through potentiometers) for both output channels. |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC/DC Power. or 20 to 70 VDC. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
|
||
Product Details:
| Voltage Type | AC |
| Brand | Ashe |
| Model | TX-250 |
| Country of Origin | Made in India |
|
AC VOLTAGE TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-250. |
|
Type |
: |
AC Voltage signal isolation, buffering and amplification. |
|
Input signal |
: |
0 to 220 V AC (or, as required – please specify). |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load |
: |
600 Ohms. |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external – through potentiometers). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify]. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
Product Details:
| Usage/Application | Industrial |
| Linearity | +/- 0.1% |
| Brand | ASHE |
| Product Type | DC Voltage Transducer |
| Model Number | TX-235 |
| Accuracy | +/-0.1% |
| Country of Origin | Made in India |
| Input Signal | 0 to 10 Volts DC [or as required] |
| Output Signal | 0 to 10 Volts DC [or as required] |
| Isolation Level | 1.5 kV rms for one minute |
| Dimensions | 100 x 22 x 110 mm[H x W x D] |
|
DC VOLTAGE ISOLATOR TRANSDUCER. |
||
|
|
|
|
|
Model |
: |
ASHE TX-235. |
|
Type |
: |
Analog signal isolation, buffering and amplification. |
|
Input signal |
: |
0 to 10 V DC |
|
Output signal |
: |
0 to 10 V DC. |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external – through potentiometer). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify]. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
Product Details:
| Brand | ASHE |
| Linearity | 0.1% |
| Accuracy | 0.1% |
| Country of Origin | Made in India |
| Model Number | TX-230 |
| Input Signal | 4 to 20 mA DC |
| Output Signal | 4 to 20 mA DC [or as required] |
| Load Driving Capacity | 600 Ohms |
| Power Supply | 85 to 270 V AC,50/60 Hz Universal AC power[Optionally 20 to 70 VDC |
|
6. SIGNAL ISOLATOR TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-230. |
|
Type |
: |
Analog signal isolation, buffering and amplification. |
|
Input signal |
: |
4 to 20 mA DC. |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify]. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
Terminations |
: |
2.5 sq mm. |
Product Details:
| Brand | ASHE |
| Model Number | TX-205 |
| Country of Origin | Made in India |
| Input Signal | mV or Volts DC [As required] |
| Output Signal | 4 to 20 mA DC [or as required] |
| Load Driving Capacity | 600 Ohms |
| Linearity | 0.1% |
| Isolation Level | 1.5 kV rms for one minute |
| Power Supply | 85 to 270 V AC,50/60 Hz Universal AC power. [Optionally 20 to 70 V DC] |
|
1. DC VOLTAGE ISOLATING TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-205. |
|
Type |
: |
Analog signal isolation, buffering and amplification. |
|
Input signal |
: |
0 to 75 mV DC or DC Voltage as required. |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external potentiometers). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify] |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upton 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
|
|
|
|
|
||
Product Details:
| Brand | ASHE |
| Linearity | 0.1% |
| Country of Origin | Made in India |
| Model Number | TX-245 |
| Input Signal | 4 to 20 mA DC |
| Output Signal | 0 to 10 V DC |
| Isolation Type | Optical and Galvanic |
| Isolation Level | 1.5 kV rms for one minute |
| Dimensions | 100 x 22 x 110 mm [H x W x D] |
|
CURRENT TO VOLTAGE TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-245. |
|
Type |
: |
Analog signal isolation, buffering and amplification. |
|
Input signal |
: |
4 to 20 mA DC. |
|
Output signal |
: |
0 to 10 V DC |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (by external potentiometers). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify]. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
Product Details:
| Brand | ASHE |
| Model Number | TX-150 |
| Input Signal | 0 to 230 V AC |
| Isolation Level | 1.5 kV rms for one minute |
| Linearity | 0.25% |
| Output Signal | 4 to 20 mA DC |
| Power Supply | 1.5 kV rms for one minute |
The ASHE TX series of Signal Conditioners, Isolators, Transducers and Transmitters comprise a wide range of high quality and reliable instruments for the conversion, amplification and isolation of analog and digital signals. The instruments accept standard industrial process input signals such as DC/AC Voltage, DC/AC Current, 4 to 20 mA DC, RTD Pt-100 sensor, Thermocouple sensor, Frequency [Pulse], Resistance, Strain-gauge, etc. and provide a buffered and isolated output with enhanced load driving capacity.
The instruments find wide usage in single loop or distributed process measurement and control applications. The new Series TX-250 AC Voltage Signal Isolating Transducers measure a variable AC Voltage and convert the signal into an isolated DC Current signal [or as required]. The Output signal is linear with respect to the Input signal and is galvanically and optically isolated to a potential level of 1.5 KV rms for one minute. The instruments operate on 65 to 285 Volts AC mains power supply or 20 to 70 Volts DC Power Supply. Optional features include Signal repeating [multiple isolated outputs], higher load driving capability, digital indication facility, control relay outputs, two-wire operation with auxillary power output, etc.
The instruments are available in compact industrial grade enclosures in DIN Rail / Wall-mounting execution, or optionally in IP65 protected field mount weather-proof enclosures, or in CIMFR certified explosion-proof enclosures. Absence of any moving parts provides these instruments inherent advantages like immunity to mechanical shocks, dust, ambient temperature, humidity and corrosive atmosphere.
Product Details:
| Brand | ASHE |
| Country of Origin | Made in India |
| Model Number | TX-125 |
| Input Signal | Frequency signal from 0 to 10 kHz |
| Output Signal | 4 to 20 mA DC [or as required] |
| Load Driving Capacity | 600 Ohms |
| Linearity | 0.1% |
| Power Supply | 110 V AC or 230 V AC, 50 hz [Optionally 20 to 70 V DC] |
| Dimensions | 75 x 55 x 110 mm [H x W x D] |
|
FREQUENCY TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-125. |
|
Type |
: |
Frequency signal isolation, buffering and amplification. |
|
Input signal |
: |
0 to 10 Khz (or as required). |
|
Signal level |
: |
12 V DC. |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Linearity |
: |
±0.15%. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external). |
|
Power Supply |
: |
230 V AC [±15%], 50 Hz. |
|
Dimensions |
: |
75 x 55 x 110 mm |
|
Execution |
: |
DIN Rail mounting. |
|
Terminations |
: |
2.5 sq mm. |
Product Details:
| Usage/Application | Industrial |
| Brand | ASHE |
| Model Number | HTR-92 |
| Country of Origin | Made in India |
| Power | 4-20 mA DC |
| Communication | RS485 communication |
The ASHE Series HTR are a range of micro-controller based instruments for the measurement and retransmission of Relative Humidity and Temperature, offered in a compact and portable execution. The instrument has three control Keys on the front panel, through which the Operator can set the parameters and configure the instrument as desired.
The instrument uses a precision RH+T Sensor and is factory calibrated for accurate display of ambient temperature and relative humidity.
The instrument provides two analog retransmission signals of 4-20 mA DC proportional to the measured Relative Humidity and Temperature for process control or logging purposes. It also offers a RS485 communication signal (on Modbus RTU protocol) of these parameters, for remote monitoring. The instrument operates on 24 VDC and is offered in a rugged polycarbonate enclosure in wall-mount execution. The bright OLED display provides clear indications of the relative Humidity and Temperature values.
Product Details:
| Transducer Type | AC Current |
| Input | 0 to 1A or 0 to 5A AC from CT secondary |
| Brand | ASHE |
| Linearity | 0.1% |
| Accuracy | 0.25% |
| Mounting Type | DIN Rail |
| Ambient Temperature | 0 to 55 deg C |
| Country of Origin | Made in India |
| Dimensions | 75 x 55 x 110 mm. [H x W x D] |
| Input Signal | 0 to 1 Ampere AC or 0 to 5 Ampere AC |
| Isolation Level | 1.5 kV rms for one minute |
| Load Driving Capacity | 600 Ohms for each output |
| Model Number | TX-122 |
| Output Signal | Two isolated outputs of 4 to 20 mA DC |
| Power Supply | 110 V AC or 230 V AC,50 Hz |
|
AC CURRENT ISOLATING TRANSDUCER (Dual Output). |
||
|
|
||
|
Model |
: |
ASHE TX-122. |
|
Type |
: |
Analog signal multiplication with isolation, buffering and amplification. |
|
Input signal |
: |
0 to 1 or 5 Ampere AC (from CT secondary). |
|
Output |
: |
Two nos. isolated linear analog signals. |
|
Output signal 1 |
: |
4 to 20 mA DC |
|
Output signal 2 |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms for each output. |
|
Accuracy class |
: |
±0.5%. |
|
Isolation |
: |
Between Input // Outputs // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (by external potentiometers) for both output channels. |
|
Power Supply |
: |
230 V AC [±15%], 50 Hz. |
|
Dimensions |
: |
75 x 55 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
Terminations |
: |
2.5 sq mm. |
Additional Information:
Product Details:
| Transducer Type | Buffer Amplifier |
| Linearity | 0.1% |
| Brand | ASHE |
| Product Type | Servo Valve Signal Isolator Converter (bipolar) |
| Model Number | TX-108 |
| Country of Origin | Made in India |
| Dimensions | 75 x 55 x 110 mm [H x W x D] |
| Isolation Level | 1.5 kV rms for one minute |
| Isolation Type | Optical and Galvanic |
| Output Signal | 4 to 20 mA DC. |
The ASHE TX series of Signal Conditioners, Isolators, Transducers, Multipliers and Buffer Amplifiers comprise a wide range of high quality and reliable instruments for the conversion, amplification and isolation of analog and digital signals. The instruments accept standard industrial process input signals such as DC/AC Voltage, DC/AC Current, 4 to 20 mA DC, RTD Pt-100 sensor, Thermocouple sensor, Frequency [Pulse], Resistance, etc. and provide a buffered and isolated output with enhanced load driving capacity. The instruments find wide usage in single loop or distributed process measurement and control applications.
The new Series TX-108 Bipolar Signal Isolating Buffer Amplifier Transducers accept a variable bipolar analog Current or Voltage signal and buffer this signal into one or more isolated analog current signal of 4 to 20 mA DC [or as required]. The Output signal is linear with respect to the Input signal and is galvanically and optically isolated to a potential level of 1.5 KV rms for one minute. The instrument is used for signal conditioning of Servo Valves like Moog, where the input signal is bipolar. The instruments operate on 65 to 285 Volts AC 50/60 Hz mains power supply. Optional features include Signal repeating [multiple isolated outputs], higher load driving capability, digital indication facility, control relay outputs, two-wire operation with auxillary power output, etc. The instruments are available in compact industrial grade enclosures in DIN Rail / Wall-mounting execution, or optionally in IP65 protected field mount weather-proof enclosures, or in CIMFR certified explosion-proof enclosures. Absence of any moving parts provides these instruments inherent advantages like immunity to mechanical shocks, dust, ambient temperature, humidity and corrosive atmosphere.
Product Details:
| Brand | ASHE |
| Country of Origin | Made in India |
| Model | TX-120 |
| Input Signal | 0 to 1 Ampere / 5 Ampere [from CT secondary] |
| Output Signal | 4 to 20 mA DC [or as required] |
| Load Driving Capacity | 600 Ohms |
| Dimensions | 75 x 55 x 110 mm [H x W x D] |
| Power Supply | 110 V AC or 230 V AC, 50 hz. [Optionally 20 to 70 V DC] |
|
AC CURRENT TRANSDUCER (A/mA) |
||
|
|
||
|
Model |
: |
ASHE TX-120. |
|
Type |
: |
Analog signal isolation, buffering and amplification. |
|
Input signal |
: |
0 to 1 Ampere or 5 Ampere AC (from CT secondary). |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external – through potentiometer). |
|
Power Supply |
: |
230 V AC [±15%], 50 Hz. |
|
Dimensions |
: |
75 x 55 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
Terminations |
: |
2.5 sq mm. |
Product Details:
| Brand | Ashe |
|
MAINS FREQUENCY TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-225. |
|
Type |
: |
Mains Frequency signal isolation, buffering and amplification. |
|
Input signal |
: |
45 to 65 Hz @ 230 VAC. |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Accuracy |
: |
±0.1%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external – through potentiometer). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [to be specified]. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
Terminations |
: |
2.5 sq mm. |
Product Details:
| Model | TX-301 |
| Country of Origin | Made in India |
Product Details:
| Model | TX-305 |
| Country of Origin | Made in India |
Product Details:
| Country of Origin | Made in India |
| Brand | Ashe |
| Input Signal | 0 to 1 K-Ohm [or as required] |
| Output Signal | 4 to 20 mA DC [or as required] |
| Linearity | +/- 0.1% |
| Isolation Type | Optical and Galvanic |
| Isolation Level | 1.5 kV rms for one minute |
| Dimensions | 100 x 22 x 110 mm [H x W x D] |
| Model Number | TX-240 |
|
RESISTANCE ISOLATING TRANSDUCER. |
||
|
|
||
|
Model |
: |
ASHE TX-240. |
|
Type |
: |
Resistance to Current Signal Isolating Transducer. |
|
Input |
: |
0 to 10 K Ohms variable resistance [or as required]. |
|
Output |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (by external potentiometers). |
|
Linearity |
: |
±0.1%. |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify]. |
|
Operating Temp |
: |
55OC. |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
Product Details:
| Brand | ASHE |
| Country of Origin | Made in India |
| Model | TX-215 |
| Output Signal | 4 to 20 mA DC [or as required] |
| Isolation Level | 1.5 kV rms for one minute |
| Accuracy | 0.1% |
| Power Supply | 85 to 270 V AC,50/60 Hz Universal AC power. [Optionally 20 to 70 V DC] |
| Dimensions | 100 x 22 x 110 mm. [H x W x D] |
|
TEMPERATURE TRANSDUCER [THERMOCOUPLE SENSOR]. |
||
|
|
||
|
Model |
: |
ASHE TX-215. |
|
Type |
: |
Temperature sensor signal isolation, buffering and amplification. |
|
Input signal |
: |
Thermocouple, Type J,K,R,S,T. [to be specified] |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Temp Range |
: |
To be specified. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC. [to be specified] |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
50OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
Terminations |
: |
2.5 sq mm. |
Product Details:
| Brand | ASHE |
| Application | Industrial |
| Country of Origin | Made in India |
| Accuracy | +/-0.1% |
| Model | TX-210 |
| Input Sensor | RTD Pt-100 [three-wire] |
| Output Signal | 4 to 20 mA DC |
| Load Driving Capacity | 600 Ohms |
| Linearity | +/-0.15% |
| Power Supply | 90 to 270 V AC,50 Hz [Optionally 20 to 70 V DC] |
| Dimensions | 100 x 22 x 110 mm. [H x W x D] |
|
TEMPERATURE TRANSDUCER [RTD SENSOR]. |
||
|
|
||
|
Model |
: |
ASHE TX-210. |
|
Type |
: |
Temperature sensor signal isolation, buffering and amplification. |
|
Input signal |
: |
RTD Pt-100 (three-wire). |
|
Output signal |
: |
4 to 20 mA DC. |
|
Load capacity |
: |
600 Ohms. |
|
Temp Range |
: |
To be specified. |
|
Accuracy |
: |
± 0.15%. |
|
Isolation |
: |
Between Input // Output // Power Supply. |
|
Isolation type |
: |
Optical and Galvanic. |
|
Isolation level |
: |
1.5 KV rms for 1 minute. |
|
Indication |
: |
Red LED for Power On. |
|
Calibration |
: |
Zero and Span settings (external – through potentiometer). |
|
Power Supply |
: |
90 to 270 VAC, 50/60 Hz Universal AC Power. Optionally 20 to 70 VDC [please specify] |
|
Dimensions |
: |
100 x 22 x 110 mm [H x W x D]. |
|
Execution |
: |
DIN Rail mounting. |
|
Operating Temp |
: |
55OC. |
|
Humidity |
: |
Upto 90% RH. |
|
Enclosure |
: |
Industrial grade ABS. |
|
Terminations |
: |
2.5 sq mm. |
Product Details:
| Wire Type | 3 Wire |